|
|
|
|
|
|
|
|
|
Wheelock 109209 005 - HORN STROBE EXPLOSION PROOF 24V RED LENS RED FINISH
|
Wheelock 109209010 - HORN STROBE COMBO 24 VOLT CLEAR LENS RED FINISH
|
|
|
|
|
|
|
|
|
|
|
Wheelock 122350 - HORN STROBE BLUE LENS 24 VOLT WHITE MULTI CANDELLA
|
Wheelock 122412 - HORN STROBE 24DC NO WORDING RED LENS MULTI CANDELLA
|
|
|
|
|
|
|
|
|
|
|
Wheelock 126097 - HORN STROBE WEATHERPROOF WORDING AGENT RED
|
REPLACES WH-127424 These Wheelock horn strobes are two-wire devices with a strobe listed at 15 cd, but providing 75 cd on axis. They offer tone choices of either continuous horn or temporal pattern (Code 3) horn when constant voltage from the fire alarm control panel (FACP) is applied. Each tone has three volume levels that can be selected at installation (field-selectable). These horn strobes can be synchronized with the SM (single) or DSM (dual) modules or a compatible control panel. The audible response can be silenced while maintaining strobe activation, a requirement in some jurisdictions. Models for 12 VDC or 24 VDC, filtered or unfilteredSelectable continuous horn or temporal (Code 3) tones each with three selectable volume settingsListed at 15 cd, but providing 75 cd on axisSynchronize with SM or DSM modulesCost-efficient two-wire operation with low profile designADA, NFPA, ANSI compliant
|
|
|
|
|
|
|
|
|
|
|
|
These Wheelock horn strobes are two-wire devices with a strobe listed at 15 cd, but providing 75 cd on axis. They offer tone choices of either continuous horn or temporal pattern (Code 3) horn when constant voltage from the fire alarm control panel (FACP) is applied. Each tone has three volume levels that can be selected at installation (field-selectable). These horn strobes can be synchronized with the SM (single) or DSM (dual) modules or a compatible control panel. The audible response can be silenced while maintaining strobe activation, a requirement in some jurisdictions. Models for 12 VDC or 24 VDC, filtered or unfilteredSelectable continuous horn or temporal (Code 3) tones each with three selectable volume settingsListed at 15 cd, but providing 75 cd on axisSynchronize with SM or DSM modulesCost-efficient two-wire operation with low profile designADA, NFPA, ANSI compliant
|
These Wheelock horn strobes are two-wire devices with a strobe listed at 15 cd, but providing 75 cd on axis. They offer tone choices of either continuous horn or temporal pattern (Code 3) horn when constant voltage from the fire alarm control panel (FACP) is applied. Each tone has three volume levels that can be selected at installation (field-selectable). These horn strobes can be synchronized with the SM (single) or DSM (dual) modules or a compatible control panel. The audible response can be silenced while maintaining strobe activation, a requirement in some jurisdictions. Models for 12 VDC or 24 VDC, filtered or unfilteredSelectable continuous horn or temporal (Code 3) tones each with three selectable volume settingsListed at 15 cd, but providing 75 cd on axisSynchronize with SM or DSM modulesCost-efficient two-wire operation with low profile designADA, NFPA, ANSI compliant
|
|
|
|
|
|
|
|
|
|
|
|
These Wheelock horn-strobes are two-wire devices that provide strobe choices of 15 cd, 30 cd, 75 cd, or 95 cd (MCC ceiling-mount models) or 15 cd, 30 cd, 75 cd, or 110 cd (MCW wall-mount models). They offer tone choices of either continuous horn or temporal pattern (Code 3) tone when constant voltage from the fire alarm control panel (FACP) is applied. Each tone has three volume levels that can be selected at installation (field-selectable). These horn-strobes can be synchronized with the SM (single) and DSM (dual) modules or a compatible control panel. The audible response can be silenced while maintaining strobe activation, a requirement in some jurisdictions. 24 VDC, filtered or unfilteredWall mount (MCW models) or ceiling mount (MCC models)Selectable continuous horn or temporal (Code 3) tones each with three selectable volume settingsSynchronize with SM and DSM modulesCost-efficient two-wire operation with low profile designADA, NFPA, ANSI compliant
|
These Wheelock horn-strobes are two-wire devices that provide strobe choices of 15 cd, 30 cd, 75 cd, or 95 cd (MCC ceiling-mount models) or 15 cd, 30 cd, 75 cd, or 110 cd (MCW wall-mount models). They offer tone choices of either continuous horn or temporal pattern (Code 3) tone when constant voltage from the fire alarm control panel (FACP) is applied. Each tone has three volume levels that can be selected at installation (field-selectable). These horn-strobes can be synchronized with the SM (single) and DSM (dual) modules or a compatible control panel. The audible response can be silenced while maintaining strobe activation, a requirement in some jurisdictions. 24 VDC, filtered or unfilteredWall mount (MCW models) or ceiling mount (MCC models)Selectable continuous horn or temporal (Code 3) tones each with three selectable volume settingsSynchronize with SM and DSM modulesCost-efficient two-wire operation with low profile designADA, NFPA, ANSI compliant
|
|
|
|
|
|
|
|
|
|
|
Description: The Series ASR Audible and Audible Strobe products provide a range of warning alarms and strobes designed to cope with harsh environments providing weatherproof protection. Design features are incorporated to ensure safer and easier installation, while providing flexibility with fewer product variants. Features: up to 120dB(A) Output Three stage alarm (2 programmable - 1 standard) More light where required with asymmetric lens Easy access for installation with shallow base format 42 Tones Weatherproof - Indoor/Outdoor Current: ASR-DC 450MA/MAX ASR-AC 115VAC - 130 MA 230VAC - 65 MA ASRS-DC Max 700 MA Nominal Voltage: 18 - 30VDC, 115/230VAC Current Consumption (tone dependant): Between Sound Output (tone dependant): Between 105 - 102dB Alarm Tones: 42 IP Rating: IP66 Lens Colour: Red / Amber / Blue Flash Rate: 1 Hz (60 per min) Color: Off White Strobe Type: U-Tube Operating Tempature: -25oC to 70oC Monitoring Mode: Polarizing Diode (DC models only) Volume Control: 0 to -10dB
|
Designed for life safety, performance and reliability, Cooper Wheelock’s cost effective weatherpoof notification appliances include: Weatherproof Appliances Series Strobes: SSWP Horn Strobes: ASWP Horns: AH-24WP, AH-12WP Multitone Horn Strobes: MTWP Multitone Horns: MT Speaker Strobes: ET70WP Speakers: ET-1010 All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of –31°F to 150°F (-40°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Cooper-Wheelock provides the industry’s widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (IOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA and WFPA kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. When used in conjunction with Wheelock PS-24-8MC Power Supplies or SM/DSM Sync Modules, the Wheelock weatherproof appliances can be synchronized to meet NFPA 72 synchronization requirements. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones. Features: • Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP) . See agency approvals by model number on page two of this document • Compliance with the following requirements: NFPA, UFC, ANSI 117.1, OSHA Part 29, 1910.165, ADA • Weatherproof with extended temperature range of –40°F to 150°F (-40°C to 66°C)* • Dual Listed strobe models (UL 1638 and UL 1971) • Industry’s highest strobe candela options • Synchronization capability using Series SM, DSM Synch Modules (MTWP and MT-12/24 audible is non-sync) • Models with field selectable tone, dBA and candela settings • Wall or ceiling mounting options • Surface of semi-flush mounting • IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal | Candela Ratings | | Series | UL 1971 | UL 1638 @ 77°F | UL 1638 @ -40°F | RSS, ET70WP and MTWP UL Max Current (Strobe Only) | ASWP | | @ 32º-120ºF | High | Med | Low | | 2475 | 30 | 180 | 115 | 0.138 | 0.168 | 0.155 | 0.15 | | MCWH | 135 | 135 | 65 | 0.3 | 0.355 | 0.34 | 0.335 | | 185 | 185 | 90 | 0.42 | 0.48 | 0.465 | 0.46 | | MCCH | 115 | 115 | 50 | 0.3 | 0.355 | 0.34 | 0.335 | | 177 | 177 | 75 | 0.42 | 0.48 | 0.465 | 0.46 | | 24185 | 185 | 185 | 90 | 0.42 | | | 24177 | 177 | 177 | 75 |
|
|
|