You are here: Home > Shop Brands > IEI International Electronics Inc. > Access Control Locksets > Access Control Deadbolt Locksets
We found 3 results matching your criteria.
Sort By:
Page of 1
IEI IE-LS1D26DAM Access Control Deadbolt Lockset IEI IE-LS1D26DCR Access Control Lockset Deadbolt Version
LS-series Features:

  • Non-volatile eeprom memory allows in-shop programming

  • One non-handed unit for both indoor and outdoor applications

  • Wire Raceway provides clean installationand protects wires inside door

  • Programs the same as all IEI products

  • Durable alphanumeric Braille keys

  • Selective Lockout of groupd of users

  • Passage/Toggle codes allow door to remain unlocked

  • Service codes allow one-time entry then are deleted automatically

  • Error Lockout for successive invalid attempts

  • Two Stage Low Battery Alert assures entry

  • Propped Door and Forced Door alerts when used with a standard magnetic switch

  • Request to Exit allows door to be unlocked from a distance

  • Four standard AA batteries provide up to 150,000 operations.


    LS-1:

  • Keypad programmable with Master Code

  • 120 individual user codes including Master, Supervisor and Emergency


    Deadbolt:

    This lockset retrofits most ANSI 115.1 Mortise with Deadbolt prepped doors with the additional of (2) through holes. The LS Series Deadbolt lockset can be easily installed in a door with an existing mortise and deadbolt lock.

    Lock Body: Grade 1 Mortise Lock body with Deadbolt

    Latch: Stainless Steel Deadbolt with 1 projection, latchbolt with 1 3/4 projection and deadlocking latch. Deadbolt may be projected from option 1 3/4 mortise cylinder with cover cam or thumb turn from inside door

    Privacy Setting feature available

    Cylinder: Solid Brass 1 1/8 Schlage C keyway, 6 pin mortise cylinder, with (2) nickel silver keys. To project deadbolt from outside door requires a 1 3/4 mortise cylinder. 1 1/8 and 2 can be used with optional spacers and a straight cam

    Optional Cylinders: see configuration guide for details


    Specifications:

    General:

    Backset: 2 3/4 Standard

    Strike: 4 7/8 ASA Strike

    Door Thickness: 1 5/8 to 1 7/8

    Handing: Field reversible on Crescent and American handles, Monaco handle must be ordered with right or left handing specified


    Compliance:

    ANSI 156.2, Series 4000 Grade 1

    Federal Handicap and ANSI A117.1 Accessibility Code

    Federal FF-H-106C

    California: (Formerly Title 19, State Fire Marshall)


    Environmental:

    Electronics sealed in conformal coating process

    Through door wire raceway reduces wire exposure to moisture

    Neoprene gasket seals exterior housing

    -20F to 120F, up to 98% humidity (non-condensing)


    Electrical:

    Power: 4 AA alkaline batteries

    Cycles: Up to 150,000

  • LS-series Features:

  • Non-volatile eeprom memory allows in-shop programming

  • One non-handed unit for both indoor and outdoor applications

  • Wire Raceway provides clean installationand protects wires inside door

  • Programs the same as all IEI products

  • Durable alphanumeric Braille keys

  • Selective Lockout of groupd of users

  • Passage/Toggle codes allow door to remain unlocked

  • Service codes allow one-time entry then are deleted automatically

  • Error Lockout for successive invalid attempts

  • Two Stage Low Battery Alert assures entry

  • Propped Door and Forced Door alerts when used with a standard magnetic switch

  • Request to Exit allows door to be unlocked from a distance

  • Four standard AA batteries provide up to 150,000 operations.


    LS-1:

  • Keypad programmable with Master Code

  • 120 individual user codes including Master, Supervisor and Emergency


    Deadbolt:

    This lockset retrofits most ANSI 115.1 Mortise with Deadbolt prepped doors with the additional of (2) through holes. The LS Series Deadbolt lockset can be easily installed in a door with an existing mortise and deadbolt lock.

    Lock Body: Grade 1 Mortise Lock body with Deadbolt

    Latch: Stainless Steel Deadbolt with 1 projection, latchbolt with 1 3/4 projection and deadlocking latch. Deadbolt may be projected from option 1 3/4 mortise cylinder with cover cam or thumb turn from inside door

    Privacy Setting feature available

    Cylinder: Solid Brass 1 1/8 Schlage C keyway, 6 pin mortise cylinder, with (2) nickel silver keys. To project deadbolt from outside door requires a 1 3/4 mortise cylinder. 1 1/8 and 2 can be used with optional spacers and a straight cam

    Optional Cylinders: see configuration guide for details


    Specifications:

    General:

    Backset: 2 3/4 Standard

    Strike: 4 7/8 ASA Strike

    Door Thickness: 1 5/8 to 1 7/8

    Handing: Field reversible on Crescent and American handles, Monaco handle must be ordered with right or left handing specified


    Compliance:

    ANSI 156.2, Series 4000 Grade 1

    Federal Handicap and ANSI A117.1 Accessibility Code

    Federal FF-H-106C

    California: (Formerly Title 19, State Fire Marshall)


    Environmental:

    Electronics sealed in conformal coating process

    Through door wire raceway reduces wire exposure to moisture

    Neoprene gasket seals exterior housing

    -20F to 120F, up to 98% humidity (non-condensing)


    Electrical:

    Power: 4 AA alkaline batteries

    Cycles: Up to 150,000

  • IEI IE-LS2D26DCR LS2 Lock With Deadbolt
    LS-series Features:

  • Non-volatile eeprom memory allows in-shop programming

  • One non-handed unit for both indoor and outdoor applications

  • Wire Raceway provides clean installationand protects wires inside door

  • Programs the same as all IEI products

  • Durable alphanumeric Braille keys

  • Selective Lockout of groupd of users

  • Passage/Toggle codes allow door to remain unlocked

  • Service codes allow one-time entry then are deleted automatically

  • Error Lockout for successive invalid attempts

  • Two Stage Low Battery Alert assures entry

  • Propped Door and Forced Door alerts when used with a standard magnetic switch

  • Request to Exit allows door to be unlocked from a distance

  • Four standard AA batteries provide up to 150,000 operations.


    LS-2:

  • 2,000 individual users per lockset

  • 2,000 transactions stored per lockset

  • Wireless lockset programming and audit trail retrieval with PDA running Palm OS version 3.5 or newer

  • Managed with HubManager Professional Software version 4 or newer

  • Unlimited Access Levels including Time Zones and Holidays

  • 10,000 users per system

  • Unlimited Sites

  • Import user names:


    Communications:

    The LS-2 & 2P offer the unique ability to communicate through a Hand Held PDA to Hub Manger Professional Software, Version 4.0 or higher.

    Realize the benefits of a traditional door controller with the ease of Stand Alone Installation

    The luxury of uploading and downloading (via PDA);

    Users

    Access Levels

    Transaction Logs

    Visit this page for a list of compatible PDA devices

  •    
     
     
     

    Enter your email for a chance to WIN $100 Amex Gift Card.

    Please Enter Your Email Address

    *One entry per household please