Wheelock AH12R
These Wheelock horns offer tone choices of either continuous horn or temporal pattern (Code 3) tone when constant voltage from the Fire Alarm Control Panel (FACP) is applied. Each tone has three field-selectable volume levels. These horns can be synchronized when used with the SM (single) and DSM (dual) Synchronization Modules or a compatible control panel. If not synchronized, the temporal sound patterns might overlap and not be distinctive.
Wheelock AH12W
Wheelock AH12WPR
Wheelock AH24R
The Wheelock NH Series horns have a choice of two tone patterns (continuous or temporal [Code 3] horn tones) and two sound output levels (high [95 dBA] or low [90 dBA]). The temporal (Code-3) horn pattern meets ANSI/NFPA/ISO requirements for standard emergency evacuation signaling. These two-wire horns feature low current draw on either 12 VDC or 24 VDC, filtered (FWR) or unfiltered. All inputs are polarized for compatibility with standard reverse polarity supervision of the circuit wiring by the control panel. The temporal patterns can be synchronized with an SM (single) or a DSM (dual) synchronization module or a compatible control panel. They have a universal mounting plate for easy wall mounting on a variety of back boxes.
Features
The Fire-Lite AUDIO-COMMAND-CENTER-25/50 (ACC-25/50) is a state-of-the-art, single- or dual-circuit (25 watts each) Emergency Voice Evacuation Control Panel (EVAC). The ACC-25/50 provides the ability to record five field-programmable messages (up to 60 seconds total message duration) with an integral commercial-grade emergency communications microphone or from an external audio source.
Significant technological enhancements set the ACC-25/50 apart from other EVAC panels these include full supervision in both active (alarm or music) and standby conditions, supervision of amplifier outputs, field wiring, message generator, all tone generators, and the microphone. The integral power supply is capable of charging up to 18 AH batteries, which can be housed in the ACC-25/50 cabinet.
The ACC-25/50 is suitable for use as an adjunct (slave or stand-alone) to most UL-Listed Fire Alarm Control Panels (FACPs). An optional 25 watt, 25 VRMS audio amplifier is available for system expansion to 50 watts (providing dual 25-watt speaker circuits) or as a secondary amplifier in jurisdictions requiring such backup. A 70.7 VRMS converter is also available for independently converting amplifiers to meet retrofit needs. A host of field-programming options, including the capability of five custom messages (fire, tornado, evacuation, hazmat, non-fire, multi-language, etc.) make the ACC-25/50 the most versatile voice evacuation system available.
Some Suitable Applications: Schools Auditoriums Dormitories Theatres Restaurants Places of Worship Lodging Office Buildings Factories
STANDARD FEATURES Integral 25 watt, 25 VRMS audio amplifier with single Style Z (Class A) or Style Y (Class B) speaker circuit (expandable to 50 watts using the ACC-AAM25). Modular design for maximum system flexibility and ease of service. Five Command Input Circuits (CMD) are available for activation by an FACP. Two command input circuits can be independently field programmed for activation by a Notification Appliance Circuit (NAC) or contact closure. Three command input circuits activate on contact closure. Manual deactivation of speaker zones. Command inputs allow: One 60-second message. Two 30-second messages. Three 20-second messages. Four 15-second messages. Five 12-second messages. Microphone time-out feature. Nineteen different system and diagnostic LEDs. Two Form-C trouble relays (System & AC Power Loss). Optional equipment: second amplifier; local playback speaker; and remote microphone. Integral digital message generator with standard, factory- prerecorded emergency evacuation message.
The Audio Command Center-25/50 Zoned System (ACC-25/50ZS) is a state-of-the-art Emergency Voice Evacuation Panel (EVAC) capable of splitting 25 or 50 watts of audio power into up to eight speaker circuits (i.e., zones). The ACC-25/50ZS provides the ability to record five field-programmable messages (up to 60 seconds total message duration) with an integral commercial-grade emergency communications microphone or from an external audio source. Significant technological enhancements set the ACC-25/50ZS apart from other EVAC panels these include full supervision in both active alarm and standby conditions, supervision of amplifier outputs, field wiring, message generator, all tone generators, and the microphone. The integral power supply is capable of charging up to 18 AH batteries, which can be housed in the ACC-25/50ZS cabinet.
The ACC-25/50ZS is suitable for use as an adjunct (slave or stand-alone) to most UL-Listed Fire Alarm Control Panels (FACPs). An optional 25 watt, 25 VRMS audio amplifier is available for system expansion to 50 watts or as a secondary amplifier in jurisdictions requiring such backup. A 70.7 VRMS converter is also available for independently converting amplifiers to meet retrofit needs.
The Zone Splitter Module (ACC-ZSM) divides the output of the Audio Amplifier Module(s) (ACC-AAM25) into up to eight speaker circuits (i.e., zones). The Zone Page Module with Keypad (ACC-ZPMK) provides full manual control of the speaker circuits, status indication of each of the speaker circuits, and automatic control by the FACP via the ACS serial link connection on the MS-9200UD and MS-9600 Addressable Panels. A host of field-programming options, including the capability of five custom messages (fire, tornado, evacuation, hazmat, nonfire, multi-language, etc.) make the ACC-25/50ZS the most versatile voice evacuation system available.
Some Suitable Applications:
STANDARD FEATURES 25 watts of audio power can be divided into eight Style Y (Class B) or four Style Z (Class A) speaker circuits (zones), utilizing the zone splitter module (ACC-ZSM). Full manual control of all audio zones provided by zone page module with keypad (ACC-ZPMK). Activation by the FACP using the ACS serial link and/or the five Command (CMD) inputs. ACS serial link compatible with all FireLite FACPs, depending on function. FACP automatically directs the voice message to each or all audio zones. Paging by zone or All-Call. Full status indication (normal, active, fault) of each speaker circuit. Fault indication via ACS serial link and/or the two Form-C trouble relays (System and AC Power Loss). Integral 25 watt, 25 VRMS audio amplifier with single Style Z (Class A) or Style Y (Class B) speaker circuit (expandable to 50 watts using the ACC-AAM25). Modular design for maximum system flexibility and ease of service. Two command input circuits can be independently field-programmed for activation by a Notification Appliance Circuit (NAC) or contact closure. Three command input circuits activate on contact closure.