Wheelock AH-12-R 12 VDC Electronic Horn (red) Wheelock AH-12-W 12 VDC Electronic Horn (white)
These Wheelock horns offer tone choices of either continuous horn or temporal pattern (Code 3) tone when constant voltage from the Fire Alarm Control Panel (FACP) is applied. Each tone has three field-selectable volume levels. These horns can be synchronized when used with the SM (single) and DSM (dual) Synchronization Modules or a compatible control panel. If not synchronized, the temporal sound patterns might overlap and not be distinctive.
  • Cost-effective two-wire design
  • Selectable continuous tone or temporal (Code 3) sound pattern synchronization
  • Three field-selectable sound levels
  • Weatherproof model available
  • Low average current draw; no Inrush Current
  • Compatible with SM and DSM Synchronization Modules

    Wheelock AH12R

  • REPLACES WH-107894

    These Wheelock horns offer tone choices of either continuous horn or temporal pattern (Code 3) tone when constant voltage from the Fire Alarm Control Panel (FACP) is applied. Each tone has three field-selectable volume levels. These horns can be synchronized when used with the SM (single) and DSM (dual) Synchronization Modules or a compatible control panel. If not synchronized, the temporal sound patterns might overlap and not be distinctive.

  • Cost-effective two-wire design
  • Selectable continuous tone or temporal (Code 3) sound pattern synchronization
  • Three field-selectable sound levels
  • Weatherproof model available
  • Low average current draw; no Inrush Current
  • Compatible with SM and DSM Synchronization Modules

    Wheelock AH12W

  • Wheelock AH-12WP-R 12 VDC Weatherproof Electronic Horn (red) Wheelock AH-24-R 24 VDC Electronic Horn (red)
    These Wheelock horns offer tone choices of either continuous horn or temporal pattern (Code 3) tone when constant voltage from the Fire Alarm Control Panel (FACP) is applied. Each tone has three field-selectable volume levels. These horns can be synchronized when used with the SM (single) and DSM (dual) Synchronization Modules or a compatible control panel. If not synchronized, the temporal sound patterns might overlap and not be distinctive.
  • Cost-effective two-wire design
  • Selectable continuous tone or temporal (Code 3) sound pattern synchronization
  • Three field-selectable sound levels
  • Weatherproof model available
  • Low average current draw; no Inrush Current
  • Compatible with SM and DSM Synchronization Modules

    Wheelock AH12WPR

  • These Wheelock horns offer tone choices of either continuous horn or temporal pattern (Code 3) tone when constant voltage from the Fire Alarm Control Panel (FACP) is applied. Each tone has three field-selectable volume levels. These horns can be synchronized when used with the SM (single) and DSM (dual) Synchronization Modules or a compatible control panel. If not synchronized, the temporal sound patterns might overlap and not be distinctive.
  • Cost-effective two-wire design
  • Selectable continuous tone or temporal (Code 3) sound pattern synchronization
  • Three field-selectable sound levels
  • Weatherproof model available
  • Low average current draw: no Inrush Current
  • Compatible with SM and DSM Synchronization Modules

    Wheelock AH24R

  • Wheelock AH-24-W 24 VDC Electronic Horn (white) Wheelock MT4-115-WH-VNS - MULTI TONE 15 CD 4 WIRE 115AC-SILVER STROBE
    These Wheelock horns offer tone choices of either continuous horn or temporal pattern (Code 3) tone when constant voltage from the Fire Alarm Control Panel (FACP) is applied. Each tone has three field-selectable volume levels. These horns can be synchronized when used with the SM (single) and DSM (dual) Synchronization Modules or a compatible control panel. If not synchronized, the temporal sound patterns might overlap and not be distinctive.
  • Cost-effective two-wire design
  • Selectable continuous tone or temporal (Code 3) sound pattern synchronization
  • Three field-selectable sound levels
  • Weatherproof model available
  • Low average current draw: no Inrush Current
  • Compatible with SM and DSM Synchronization Modules

    Wheelock AH24R

  • Description:


    The Wheelock Series MT and MT Strobe Multitone electronic appliances offer a choice of eight (8) nationally and internationally recognized alerting sounds: Horn, Bell, March Time Horn, Code-3 Tone, Code-3 Horn, Slow Whoop, Siren or Hi/Lo Tone. The Code-3 Horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pattern specifications without requiring additional equipment. With MT and MT Strobe appliances, one alarm appliance meets most of your signaling needs. The MT strobes can be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8MC Power Supply with the Wheelock patented Sync Protocol.
    The MT Strobes are designed for ADA applications while meeting or exceeding the latest requirements of NFPA 72, ANSI 117.1, UFC and UL Standard 1971 as well as meeting ADA requirements concerning photosensitive epilepsy.
    Each MT and MT Strobe appliance has two installer selective sound output levels: STANDARD dBA and HIGH dBA. Non-strobe versions provide selectable voltage capability in one unit, 12VDC or 24VDC. Strobe versions are specific for either 12VDC or 24VDC and all models may be used with filtered or unfiltered (full-wave-rectified) input voltages. Separate input terminals are available, shunt wires are provided to enable both tone and strobe to operate simultaneously from a single input.
    The Series MT Multitone Strobe appliances are UL Listed for indoor wall mount applications under Standard 1971 for Signaling Devices for the Hearing Impaired and under Standard 464 for Audible Signaling Appliances.

    Features:

    • Approvals include: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information
    • Designed to meet or exceed ADA/NFPA/UFC/ANSI Standards and Accessibility Guidelines
    • Complies with OSHA 29, Part 1910.165
    • Series MT appliances have IN and OUT wiring terminations that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Inputs are polarized for compatibility with standard reverse polarity type supervision
    • One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels
    • Code-3 Horn and Tone meet ANSI/NFPA temporal pattern for standard emergency evacuation signaling
    • Audible and strobe can operate from a single NAC circuit or from separate NAC circuits with any of the (8) eight audible sounds
    • MT Strobe models are available with Wheelock patented MCW Multi-Candela strobes with field selectable c andela settings at 15/30/75/110cd or with single candela 1575cd strobes. The strobes can be synchronized using Wheelock sync modules or power supplies with built in Sync Protocol
    • Selectable input voltage on non-strobe versions. Strobe versions are factory set for either 12 or 24VDC, with wide- Listed voltage range, filtered (DC) and FWR
    • No additional trimplate required for flush mounting

    Wheelock MT4-12/24-S - HORN 12 OR 24VDC 4 WIRE SILVER GRAY Wheelock NH-12/24-R HORN 12/24VOLT

    Description:


    The Wheelock Series MT and MT Strobe Multitone electronic appliances offer a choice of eight (8) nationally and internationally recognized alerting sounds: Horn, Bell, March Time Horn, Code-3 Tone, Code-3 Horn, Slow Whoop, Siren or Hi/Lo Tone. The Code-3 Horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pattern specifications without requiring additional equipment. With MT and MT Strobe appliances, one alarm appliance meets most of your signaling needs. The MT strobes can be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8MC Power Supply with the Wheelock patented Sync Protocol.
    The MT Strobes are designed for ADA applications while meeting or exceeding the latest requirements of NFPA 72, ANSI 117.1, UFC and UL Standard 1971 as well as meeting ADA requirements concerning photosensitive epilepsy.
    Each MT and MT Strobe appliance has two installer selective sound output levels: STANDARD dBA and HIGH dBA. Non-strobe versions provide selectable voltage capability in one unit, 12VDC or 24VDC. Strobe versions are specific for either 12VDC or 24VDC and all models may be used with filtered or unfiltered (full-wave-rectified) input voltages. Separate input terminals are available, shunt wires are provided to enable both tone and strobe to operate simultaneously from a single input.
    The Series MT Multitone Strobe appliances are UL Listed for indoor wall mount applications under Standard 1971 for Signaling Devices for the Hearing Impaired and under Standard 464 for Audible Signaling Appliances.

    Features:

    • Approvals include: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information
    • Designed to meet or exceed ADA/NFPA/UFC/ANSI Standards and Accessibility Guidelines
    • Complies with OSHA 29, Part 1910.165
    • Series MT appliances have IN and OUT wiring terminations that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Inputs are polarized for compatibility with standard reverse polarity type supervision
    • One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels
    • Code-3 Horn and Tone meet ANSI/NFPA temporal pattern for standard emergency evacuation signaling
    • Audible and strobe can operate from a single NAC circuit or from separate NAC circuits with any of the (8) eight audible sounds
    • MT Strobe models are available with Wheelock patented MCW Multi-Candela strobes with field selectable c andela settings at 15/30/75/110cd or with single candela 1575cd strobes. The strobes can be synchronized using Wheelock sync modules or power supplies with built in Sync Protocol
    • Selectable input voltage on non-strobe versions. Strobe versions are factory set for either 12 or 24VDC, with wide- Listed voltage range, filtered (DC) and FWR
    • No additional trimplate required for flush mounting

    REPLACES WH-128469

    The Wheelock NH Series horns have a choice of two tone patterns (continuous or temporal [Code 3] horn tones) and two sound output levels (high [95 dBA] or low [90 dBA]). The temporal (Code-3) horn pattern meets ANSI/NFPA/ISO requirements for standard emergency evacuation signaling. These two-wire horns feature low current draw on either 12 VDC or 24 VDC, filtered (FWR) or unfiltered. All inputs are polarized for compatibility with standard reverse polarity supervision of the circuit wiring by the control panel. The temporal patterns can be synchronized with an SM (single) or a DSM (dual) synchronization module or a compatible control panel. They have a universal mounting plate for easy wall mounting on a variety of back boxes.

    Features

  • Two selectable nationally and internationally recognized alerting signals
  • Two selectable sound output levels
  • 12 VDC or 24 VDC, filtered or unfiltered
  • Low average current draw
  • NFPA and ANSI compliant
  • Wheelock NH-12/24-W HORN 12/24VOLT WHITE Wheelock NH-12/24R-W - HORN ONLY ROUND WHITE CEILING MOUNT 12/24VDC HORN ONLY
    REPLACES WH-128469

    The Wheelock NH Series horns have a choice of two tone patterns (continuous or temporal [Code 3] horn tones) and two sound output levels (high [95 dBA] or low [90 dBA]). The temporal (Code-3) horn pattern meets ANSI/NFPA/ISO requirements for standard emergency evacuation signaling. These two-wire horns feature low current draw on either 12 VDC or 24 VDC, filtered (FWR) or unfiltered. All inputs are polarized for compatibility with standard reverse polarity supervision of the circuit wiring by the control panel. The temporal patterns can be synchronized with an SM (single) or a DSM (dual) synchronization module or a compatible control panel. They have a universal mounting plate for easy wall mounting on a variety of back boxes.

    Features

  • Two selectable nationally and internationally recognized alerting signals
  • Two selectable sound output levels
  • 12 VDC or 24 VDC, filtered or unfiltered
  • Low average current draw
  • NFPA and ANSI compliant
  • Description:
    The Series NS Horn Strobe Appliances are designed for indoor, wall and ceiling mount applications.
    The Series NH Horn and the horn portion of the Series NS include a selectable continuous horn tone or temporal pattern (Code 3) with selectable dBA settings of 90 or 95 dBA.
    Strobe options include 1575cd or the Wheelock patented Multi-Candela strobe with field selectable candela settings of 15/30/75/110cd for wall mount and 15/30/75/95cd and 115/177cd for ceiling mount.
    These versatile Horn Strobe Appliances can be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8MC Power Supply with the Wheelock patented Sync Protocol. Additionally, the audible may be silenced while maintaining strobe activation.
    All models of the Series NS and NH are designed for maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest requirements of NFPA 72/ANSI 117.1/UFC and UL Standards 1971 and 464 as well as meeting ADA requirements concerning photosensitive epilepsy.
    The Wheelock patented 2-Wire Series NS Horn Strobes and Series NH Horns offer more features with lower current draw than competitors.

    Features:
    • Approvals include: UL Standard 1971, UL Standard 464, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP). See approvals by model number in Specifications and Ordering Information
    • ADA/NFPA/UFC/ANSI compliant
    • Complies with OSHA 29, Part 1910.165
    • Wall mount model Field Selectable Candela Setting 15/30/75/110cd (24 VDC Multi-Candela models) or 1575cd in 12 or 24 VDC
    • Ceiling mount model Field Selectable Candela Setting 15/30/75/95cd and 115/177cd (24 VDC Multi-Candela models)
    • Selectable Continuous Horn or Temporal (Code 3)
    • 2 Selectable dBA settings of 90 and 95 dBA in both tones
    • Patented Universal Mounting Plate
    • 12 and 24 VDC models with UL “Regulated Voltage” using filtered DC or unfiltered VRMS input voltage
    • Wall and Ceiling Mount
    • Ceiling models with same look as Wheelock round ceiling strobes and speakers
    • NH horn is selectable 12 or 24 VDC in 1 appliance
    • The strobes can be synchronized using the Wheelock sync modules or power supplies with built in Sync Protocol
    • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires


    Fire-Lite ACC-25/50 EVAC - Audio Command Center / Emergency Voice Evacuation Control Panel Fire-Lite ACC-25/50ZS EVAC - Audio Command Center 25/50 Zone Splitter Voice Evacuation Control Panel
    ACC-25/50: 25 watt, 25 VRMS, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, digital message generator, and single-/dualchannel Class A or Class B speaker circuits.

    The Fire-Lite AUDIO-COMMAND-CENTER-25/50 (ACC-25/50) is a state-of-the-art, single- or dual-circuit (25 watts each) Emergency Voice Evacuation Control Panel (EVAC). The ACC-25/50 provides the ability to record five field-programmable messages (up to 60 seconds total message duration) with an integral commercial-grade emergency communications microphone or from an external audio source.

    Significant technological enhancements set the ACC-25/50 apart from other EVAC panels — these include full supervision in both active (alarm or music) and standby conditions, supervision of amplifier outputs, field wiring, message generator, all tone generators, and the microphone. The integral power supply is capable of charging up to 18 AH batteries, which can be housed in the ACC-25/50 cabinet.

    The ACC-25/50 is suitable for use as an adjunct (slave or stand-alone) to most UL-Listed Fire Alarm Control Panels (FACPs). An optional 25 watt, 25 VRMS audio amplifier is available for system expansion to 50 watts (providing dual 25-watt speaker circuits) or as a secondary amplifier in jurisdictions requiring such backup. A 70.7 VRMS converter is also available for independently converting amplifiers to meet retrofit needs. A host of field-programming options, including the capability of five custom messages (fire, tornado, evacuation, hazmat, non-fire, multi-language, etc.) make the ACC-25/50 the most versatile voice evacuation system available.

    Some Suitable Applications:
    Schools Auditoriums Dormitories Theatres
    Restaurants Places of Worship Lodging
    Office Buildings Factories

    STANDARD FEATURES
    • Integral 25 watt, 25 VRMS audio amplifier with single Style Z (Class A) or Style Y (Class B) speaker circuit (expandable to 50 watts using the ACC-AAM25).
    • Modular design for maximum system flexibility and ease of service.
    • Five Command Input Circuits (CMD) are available for activation by an FACP.
    • Two command input circuits can be independently field programmed for activation by a Notification Appliance Circuit (NAC) or contact closure.
    • Three command input circuits activate on contact closure.
    • Manual deactivation of speaker zones.
    • Command inputs allow:
    – One 60-second message.
    – Two 30-second messages.
    – Three 20-second messages.
    – Four 15-second messages.
    – Five 12-second messages.
    • Microphone time-out feature.
    • Nineteen different system and diagnostic LEDs.
    • Two Form-C trouble relays (System & AC Power Loss).
    • Optional equipment: second amplifier; local playback speaker; and remote microphone.
    • Integral digital message generator with standard, factory- prerecorded emergency evacuation message.

    ACC-25/50ZS: 25 watt, 25 VRMS, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, digital message generator, zone splitter module (ACCZSM), zone page module with keypad (ACC-ZPMK).

    The Audio Command Center-25/50 Zoned System (ACC-25/50ZS) is a state-of-the-art Emergency Voice Evacuation
    Panel (EVAC) capable of splitting 25 or 50 watts of audio power into up to eight speaker circuits (i.e., zones). The ACC-25/50ZS provides the ability to record five field-programmable messages (up to 60 seconds total message duration) with an integral commercial-grade emergency communications microphone or from an external audio source. Significant technological enhancements set the ACC-25/50ZS apart from other EVAC panels these include full supervision in both active alarm and standby conditions, supervision of amplifier outputs, field wiring, message generator, all tone generators, and the microphone. The integral power supply is capable of charging up to 18 AH batteries, which can be housed in the ACC-25/50ZS cabinet.

    The ACC-25/50ZS is suitable for use as an adjunct (slave or stand-alone) to most UL-Listed Fire Alarm Control Panels (FACPs). An optional 25 watt, 25 VRMS audio amplifier is available for system expansion to 50 watts or as a secondary amplifier in jurisdictions requiring such backup. A 70.7 VRMS converter is also available for independently converting amplifiers to meet retrofit needs.

    The Zone Splitter Module (ACC-ZSM) divides the output of the Audio Amplifier Module(s) (ACC-AAM25) into up to eight speaker circuits (i.e., zones). The Zone Page Module with Keypad (ACC-ZPMK) provides full manual control of the speaker circuits, status indication of each of the speaker circuits, and automatic control by the FACP via the ACS serial link connection on the MS-9200UD and MS-9600 Addressable Panels. A host of field-programming options, including the capability of five custom messages (fire, tornado, evacuation, hazmat, nonfire, multi-language, etc.) make the ACC-25/50ZS the most versatile voice evacuation system available.

    Some Suitable Applications:

    1. Schools
    2. Auditoriums
    3. Dormitories
    4. Theatres
    5. Restaurants
    6. Places of Worship
    7. Lodging
    8. Office Buildings
    9. Factories

    STANDARD FEATURES
    25 watts of audio power can be divided into eight Style Y (Class B) or four Style Z (Class A) speaker circuits (zones), utilizing the zone splitter module (ACC-ZSM).
    Full manual control of all audio zones provided by zone page module with keypad (ACC-ZPMK).
    Activation by the FACP using the ACS serial link and/or the five Command (CMD) inputs.
    ACS serial link compatible with all FireLite FACPs, depending on function.
    FACP automatically directs the voice message to each or all audio zones.
    Paging by zone or All-Call.
    Full status indication (normal, active, fault) of each speaker circuit.
    Fault indication via ACS serial link and/or the two Form-C trouble relays (System and AC Power Loss).
    Integral 25 watt, 25 VRMS audio amplifier with single Style Z (Class A) or Style Y (Class B) speaker circuit (expandable to 50 watts using the ACC-AAM25).
    Modular design for maximum system flexibility and ease of service.
    Two command input circuits can be independently field-programmed for activation by a Notification Appliance Circuit (NAC) or contact closure.
    Three command input circuits activate on contact closure.

       
     
     
     