You are here: Home > Shop Brands > Honeywell Security & Communications > Honeywell Expansion Modules & Accessories > Expansion Modules
We found 24 results matching your criteria.

McAfee Secure sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams

Expansion Modules

  ADEMCO
  OMNI
ADEMCO
OMNI
Sort By:
Page of 2
Ademco / Honeywell 4101SN -  V-Plex Single Output Relay Module Ademco / Honeywell 4190SN - Two-Zone Remote Point Module

The ADEMCO 4101SN V-Plex Single Output Relay Module is an accessory for use with ADEMCO control panels that support serial number addressable polling loop output devices.

The 4101SN features the following:

  • Form C relay contacts rated at 2A, 28VACNDC with contact supervision.
    The position of the relay is supervised, but not the actual external contact wiring.
    Note: Some panels may not support this feature. 
  • One class B/style B EOLR-supervised aux input zone. 
  • Operating power and communication with control panels via the addressable V-PlexTM polling loop. 
  • Electronics mounted in a small plastic case with tamper-protected cover. Suitable for residential and commercial burglary and fire installations.
Addressable Relay Module 781410197183

Specifications:

    Physical: 2 1/8" x 3 1/4" x 1" (53mm x 84mm x 25mm)

    Electrical:

  • Polling loop input voltage range: 8-14VDC
  • Addressable polling loop current draw: 7mA
  • Relay contact rating: 2A @ 28VAC/VDC, both resistive and inductive loads

    Aux Zone:

  • 10K EOLR (internal when white jumper intact; external when white jumper cut)
  • 300 ohm max zone resistance (excluding EOLR)
  • Responds to open or short circuit fault having 250ms or longer duration
  • Class B (style B when used with panels providing earth ground fault detection)

    Agency Listings:

  • UL985 Household Fire
  • UL1023 Household Burglary
  • UL609 Commercial Burglary
  • ULCommercial Fire
  • CSFM (pending)
  • FM (pending)
  • MEA (pending)
Two-Zone Remote Point Module

The ADEMCO 4190SN addressable V-PlexTM module is a two-zone expander which allows use of the available expansion zones provided by ADEMCO controls that support V-Plex devices.

  • Serial mode programmable
  • Left Zone - EOLR supervised, open or closed circuit sensors
  • Right Zone - unsupervised, closed circuit sensors
  • UL listed for fire and burglary installations
Features:

The 4190SN consists of two detection loops, known as the left (primary) and right (secondary) loops. The left loop can be used for:

  • Closed-circuit devices with or without EOLR supervision
  • Open-circuit devices, with EOLR supervision
  • Fast-response (10 millisecond) devices

Follow the chart below for cutting the correct jumpers and choosing the correct resistor when using the left loop. The right loop can be used for:

  • Closed-circuit devices only
  • Has no EOLR supervision
  • 400 millisecond response time  

The jumpers do not affect the operation of the right loop. The right loop cannot be used alone.

Supervision:

The tamper/supervision response of the 4190SN is determined by the zone response type assigned to the left loop zone. While the system is armed, tamper/supervisory faults will report as alarms if the left loop zone is assigned a burglary response type and will report as troubles if the left loop zone is assigned a non-burglary response type (i.e., fire, panic, aux). While the system is disarmed, tamper/supervisory will always report as troubles.

Specifications:

    Operating Temperature:

  • 20C to +60C

    Operating Relative Humidity:

  • 0-95% non condensing

    Operating Voltage:

  • 7-14VDC, for V-Plex System

    Quiescent Current:

  • 1.2mA (LED off), 5.0mA (LED on)

    Loop Current:

  • 2 amps, max.

    Complete Short Detection:

  • <10 ohms

    Resistive Short Detection:

  • (10-400) ohms during normal polling; (10-800) ohms at application of polling loop power

    Power-On Short Detection:

  • Overload Detection:
  • Loop power level is, 6VDC

    Dimensions:

  • 4 1/8" L x 9 1/16" W x 7/8" D

    Agency Listing:

  • UL1610 - Commercial Burglary Alarm - central station alarm units
  • UL864 - Commercial Fire Alarm
  • UL985 - Residential Fire Alarm
  • UL1023 - Household Burglary - alarm system units
  • UL609 - Commercial Burglary - local alarm units
  • UL365 - Commercial Burglary - police station alarm units
  • CUL
  • CSFM
  • FM
  • CE
Ademco / Honeywell 4204 - Intelligent Relay Board Ademco / Honeywell 4204CF - Supervised Notification Appliance Module
Intelligent Relay Board

When your installation requirements call for additional relay outputs, the 4204 is your answer. The 4204 Intelligent Relay Board adds relays which are connected to the Control/Communicator via the control's console wiring. The relay outputs are programmed by the appropriate control for a variety of functions.

The 4204 is ideal for applications that require additional sounding devices, strobe lights or other devices that need or desire to be controlled by the control panel.

The 4204 is housed in a white plastic case for wall mounting and can be mounted in a Universal Can. If the 4204 is remotely mounted, there are provisions to tamper protect the cover, and the unit so that it cannot be disconnected from the console wiring without detection be the control.

Features:

  • Adds 4 programmable relays to selected VISTA panels
  • Easily wired to control panel
  • Fits inside Universal Control Cabinet
  • Expand existing security systems with additional output capabilities
  • Attractive case design
  • Check Control Documentation for compatibility with 4204

Specifications:
  • Physical: 6 1/2" x 4 1/4" x 1 1/4" (169mm x 108mm x 32mm)
  • Electrical:
    - Voltage: 12VDC (from control's remote consloe connection points)
    - Current: 15mA standby plus 40mA per active relay

The 4204CF provides two programmable, on-board, styled B on selected panels supervised notification appliance outputs; applications include supervised bells, strobes, sirens or interface to other equipment.

Ademco / Honeywell 4208SN - Universal Eight Zone Remote Point Module Ademco / Honeywell 4208SNF - Universal Expander Module
Serialized Eight Zone Remote Point Module

The 4208SN Remote Point Module (RPM) is an eight-zone expander that allows the use of available expansion zones on Honeywell VISTA controls that support V-Plex polling loop devices.

Features:
  • Can be used on controls that support up to 250 zones
  • Can be optionally powered from an external DC power supply to reduce the amount of current draw from the polling loop
  • Uniquely identified eight EOLR supervised zones (all zones use 10K resistors, supplied)
  • Each zone is identified by a unique serial number, which is assigned via on-board DIP switches
  • Detects faults on all zones within 400ms of occurence
  • Loops A & B can be programmed for fast (10ms) response
  • Provides cover tamper protection, which may be enabled or disabled via on board DIP switches

Specifications:

    Physical:

  • 6-7/16" W x 4-1/4" H x 1-1/4" D (163mm x 108mm x 32mm)

    Electrical: Polling Loop Voltage

  • 11V nominal; 8.7 - 14VDC range

    Current:

  • 33.6mA when polling loop provides power to module, 0.6mA when 12VDC input provides power to module. See chart below.

    Input Voltage:

  • 12VDC nominal; 9.4 - 14VDC range

    Expander Sensor Loop Response:

  • Slow: 400msec (all loops)
  • Fast: 10msec (option for loops A and B)

    Expander Sensor Loop Current:

  • 0.52mA (normal)
  • 1.3mA (shorted)
    NOTE: These currents apply wneh polling loop input = 11VDC and 10VDC input is not connected to external supply

    Sensor Loop Max. Resistance:

  • Up to 300 ohms of wire resistence + 10K EOLR

    Agency Listings:

  • UL985 Household Fire
  • UL1023 Household Bulgary
  • UL609 Commercial Burglary
  • UL864 Commercial Fire
  • CSFM
  • FM (Pending)
  • CUL
  • CE (requires #N6361)

    For UL Listed Commercial Fire Usage:
    Use N.O. contacts. Style B supervise these loops using Model #EOL 100 fire listed 10K EOLRs (purchased separately).
    For UL Listed Commercial Burglary Usage: Use N.O. or N.C. contacts. Supervise using EOLRs supplied.

    Power Input SourceCurrent Draw (all zones shorted)
    From Polling LoopFrom External Power
    Polling Loop Only33.6mAN/A
    Polling Loop and External Power Input0.6mA33mA
Addressable Universal Expander Module

The ADEMCO 4208SNF Remote Point Module (RPM) is a UL listed 8 zone expander that provides (6) class B and (2) class A expansions zones to any VISTA Fire/Burg control panel that supports serial V-Plex polling loop devices.

FEATURES:
  • Can be used on controls that support up to 250 zones
  • Provides up to six Class B supervised zones using external 10k EOL resistors and two Class A supervised zones using built-in 10k EOL resistors
  • Powered from addressable loop or optionally powered from an external DC power supply to reduce current draw from the addressable loop
  • Each zone is identified by a unique serial number, which is assigned via on-board DIP switches
  • Detects faults an all zones with 400msec of occurrence. Two Class B zones can be optionally set for fast (10msec) response via on-board DIP switches
  • Provides cover tamper protection, which may be enabled or disabled via on-board DIP switches
Class B to Class A Zone Converter Features
  • Allows up to two Class B control panel zones to be converted into Class A zones
  • Control panel’s response time to faults on the module’s Class A zones is equal to the response time of the control panel’s converted Class B zones plus one msec
  • Must be powered from an external 12vdc power supply such as the 12v auxiliary power output on the control panel

Specifications:

    Physical:

  • 6-7/16" W x 4-1/4" H x 1-1/4" D (163mm x 108mm x 32mm)

    Electrical: – Addressable V-Plex loop Voltage: 11v nominal; 8.7 - 14VDC range
    - Current: 33.6mA when polling loop provides power to module; 0.6mA when 12VDC input provides power to module
    – 12VDC Input Voltage:
    12V nominal: 9.4 - 14 VDC range
    – Current: 33mA when this input provides power to module (optional)

  • Used as a Class A Converter
    – 12VDC Input Voltage:
    12VDC nominal, 9.4 - 14VDC range, –
    - Current: 22mA

    AGENCY LISTINGS:

  • UL985 Household Fire
  • UL1023 Household Burglary
  • UL609 Commercial Burglary
  • UL864 Commercial Fire
  • CSFM
  • FM
  • CUL
  • CE (requires part#N6361)

    MOUNTING INSTRUCTIONS:

    When used as a zone expander, the 4208SNF may be placed inside the control panel cabinet or mounted remotely. When used as a Class B to Class A zone converter, the 4208SNF must be placed inside the control panel cabinet.

    EXPANDER SENSOR LOOP RESPONSE:

  • Slow: 400msec (all loops)
  • Fast: 10msec (options for loops A and B)

    EXPANDER SENSOR LOOP CURRENT:

  • 0.52mA (normal)
  • 1.3mA_ (shorted)

    Note: Addressable loop input = 11VDC, no external power input required

    SENSOR LOOP MAX. RESISTANCE:

  • Loops A - F (Class 8); Up to 300 ohms of wire resistance + 10k EOLR
  • Loops G, H (Class A); Up to 150 ohms of wire resistance on each side

    Power Input Source Expander/Converter Current Draw from Addressable Loop (all zones shorted) Current Draw from External Power (all zones shorted)
    Addressable Loop Only Expander 33.6mA N/A
    Addressable Loop and External Power Input Expander 0.6mA 33mA
    External Power Input Only Converter N/A 22mA
Ademco / Honeywell 4208U - Addressable Loop Expansion Module Ademco / Honeywell 4219 - 8 Wired Zone Expander
Features
  • Can be optionally powered from an external DC power supply to reduce the amount of current draw from the polling loop
  • Uniquely identifies eight EOLR supervised zones (all zones use 10K resistors, supplied)
  • DIP Switches can be used to set zone numbers or serial numbers
  • When used in the serial number mode, each serial number in the selected group can be assigned to any zone number
  • Loops A & B can be programmed for fast (10msec) response
  • Provides cover tamper protection, which may be enabled or disabled via on-board DIP Switches

Specifications:

    Physical:

  • 6-7/16" W x 4-1/4" H x 1-1/4" D (163mm x 108mm x 32mm)

    Electrical: Polling Loop Voltage

  • 11V nominal; 8.7 - 14VDC range

    Current:

  • 33.6mA when polling loop provides power to module, 0.6mA when 12VDC input provides power to module. See chart below.

    Input Voltage:

  • 12VDC nominal; 9.4 - 14VDC range

    Expander Sensor Loop Response:

  • Slow: 400msec (all loops)
  • Fast: 10msec (option for loops A and B)

    Expander Sensor Loop Current:

  • 0.52mA (normal)
  • 1.3mA (shorted)
    NOTE: These currents apply wneh polling loop input = 11VDC and 10VDC input is not connected to external supply

    Sensor Loop Max. Resistance:

  • Up to 300 ohms of wire resistence + 10K EOLR

    Agency Listings:

  • UL985 Household Fire
  • UL1023 Household Bulgary
  • UL609 Commercial Burglary
  • UL864 Commercial Fire
  • CSFM
  • FM (Pending)
  • CUL
  • CE (requires #N6361)

    For UL Listed Commercial Fire Usage:
    Use N.O. contacts. Style B supervise these loops using Model #EOL 100 fire listed 10K EOLRs (purchased separately).
    For UL Listed Commercial Burglary Usage: Use N.O. or N.C. contacts. Supervise using EOLRs supplied.

    Power Input SourceCurrent Draw (all zones shorted)
    From Polling LoopFrom External Power
    Polling Loop Only33.6mAN/A
    Polling Loop and External Power Input0.6mA33mA
DO NOT USE WITH CARBON MONOXIDE DETECTOR

Wired Zone Expander

  • Adds up to 8 end-of-line hardwired supervised zones
  • Easily wired to Control Panel
  • Fits inside Universal Control Cabinet
  • Expand existing security systems easily
  • Attractive case design
  • Supported on VISTA-20HW

4219 WIRED ZONE EXPANDER
When your installation requirements call for an additional 8 hardwired zones for new or existing installations, the 4219 is your answer. The 4219 Wired Zone Expander adds up to 8 EOLR supervised zones which are connected to the Control/Communicator via the control's console wing

The 4219 is ideal for expanding existing hardwired jobs without changing the control panel. The ability to add multiple zone expanders to gain more hardwired zones offers maximum protection with minimum cost.

The 4219 is housed in a white plastic case for wall mounting and can be mounted in a universal cabinet. If the 4219 is remotely mounted, there are provisions that tamper-protect the unit so that it cannot be disconnected from the console wiring without detection by the control.

Specifications:

  • Dimensions: 6 1/2" x 4 1/4" x 1 1/4" (169mm x 108mm x 32 mm)
  • Electrical:
    - Voltage: 12VDC (from control's remote console connection points)
    - Current: 35mA
Ademco / Honeywell 4229 - Wired Zone Expander / Relay Board Ademco / Honeywell FSA-24 - 24-Zone LED Fire System Annunciator
DO NOT USE WITH CARBON MONOXIDE DETECTOR

Wired Zone Expander / Relay Board

  • Provides 8 end-of-line supervised zones and 2 on-board programmable form C relays
  • Connection made to the control's console wires
  • Supported on VISTA-20HW
For Use With Controls Supporting Fire System Annunciator Connection Via Keypad Lines
CAN ONLY BE USED WITH NEW VISTAFB SERIES PANELS
CAN NOT BE USED WITH NEW VISTA-9 VERSION CONTROLS PANELS

The ADEMCO 8-Zone LED Fire System Annunciator FSA-8, and 24-Zone LED Fire System Annunciator FSA-24, are add-on accessories that can be used with certain VISTA controls to provide the ability for a fire response unit to identify quickly and easily the point/zone of a fire. The LED's may also be used to annunciate other functions like monitoring door, critical equipment, etc.

A maximum of 4 FSA modules, in any combination, can be supported by the system. Each FSA module must use the ECP Bus, keypad-type protocol, and can support up to 24 LEDs dependent upon model selection. In addition, the FSA module provides power and system status with LEDs and control via Silence/Reset and Test buttons. An optional Fire System Annunciator Keyswitch Module (FSAKSM) is available to function in a manner similar to the Silence/Reset button of the FSA module. The difference between the Silence/Reset button and the FSAKSM is that when installed, the FSAKSM will unconditionally Silence and then Reset the Fire Partition, while the Silence/Reset button can be restricted from silencing or resetting the fire alarm system (dependent upon program selection. See “RST FIRE PTN”).

Since the ECP bus is used to connect the VISTA control to the FSA modules, any supported VISTA keypad may be located in proximity to the FSA module connecting to the same ECP bus. The maximum FSA system will consist of 4 FSA modules, 4 Keyswitch modules, and 4 keypads.

Up to 4 FSA modules may be located in different locations but displaying the same information via the LEDs. Alternately, they may be located in the same physical location but displaying the status of up to 96 unique zones.

Features:

  • 8 or 24 LED annunciators with sounder
  • Power and trouble LED's
  • Silence and reset switch
  • Lamp test switch
  • Fully supervised
  • Operates on Commercial VISTA Panel keypad bus
  • Up to four FSA-8 or 24 led annunciators per system
  • Optional Key-Reset Switch

SPECIFICATIONS:

  • Physical Dimensions: 8" W x 4" H x 3/4" D
  • Electrical:
    – Input Voltage: 12 VDC
    – Current: 35mA idle, 65mA all LEDs lit and sounder on
  • Ademco / Honeywell FSA-8 - 8-Zone LED Fire System Annunciator Ademco / Honeywell V-Plex VSI - V-Plex Short Isolator - VPLEX-VSI
    For Use With Controls Supporting Fire System Annunciator Connection Via Keypad Lines
    CAN ONLY BE USED WITH NEW VISTAFB SERIES PANEL
    CAN NOT BE USED WITH NEW VISTA-9 VERSION CONTROL PANELS

    The ADEMCO 8-Zone LED Fire System Annunciator FSA-8, and 24-Zone LED Fire System Annunciator FSA-24, are add-on accessories that can be used with certain VISTA controls to provide the ability for a fire response unit to identify quickly and easily the point/zone of a fire. The LED's may also be used to annunciate other functions like monitoring door, critical equipment, etc.

    A maximum of 4 FSA modules, in any combination, can be supported by the system. Each FSA module must use the ECP Bus, keypad-type protocol, and can support up to 24 LEDs dependent upon model selection. In addition, the FSA module provides power and system status with LEDs and control via Silence/Reset and Test buttons. An optional Fire System Annunciator Keyswitch Module (FSAKSM) is available to function in a manner similar to the Silence/Reset button of the FSA module. The difference between the Silence/Reset button and the FSAKSM is that when installed, the FSAKSM will unconditionally Silence and then Reset the Fire Partition, while the Silence/Reset button can be restricted from silencing or resetting the fire alarm system (dependent upon program selection. See “RST FIRE PTN”).

    Since the ECP bus is used to connect the VISTA control to the FSA modules, any supported VISTA keypad may be located in proximity to the FSA module connecting to the same ECP bus. The maximum FSA system will consist of 4 FSA modules, 4 Keyswitch modules, and 4 keypads.

    Up to 4 FSA modules may be located in different locations but displaying the same information via the LEDs. Alternately, they may be located in the same physical location but displaying the status of up to 96 unique zones.

    Features:

    • 8 or 24 LED annunciators with sounder
    • Power and trouble LED's
    • Silence and reset switch
    • Lamp test switch
    • Fully supervised
    • Operates on Commercial VISTA Panel keypad bus
    • Up to four FSA-8 or 24 led annunciators per system
    • Optional Key-Reset Switch

    SPECIFICATIONS:

  • Physical Dimensions: 4" W x 4" H x 3/4" D
  • Electrical:
    – Input Voltage: 12 VDC
    – Current: 35mA idle, 65mA all LEDs lit and sounder on
  • V-Plex Short Isolator

    Designed to work on all Honeywell V-Plex polling loops, the VPLEX-VSI provides short circuit isolation for devices on compatible control panels. When a short occurs on a polling loop branch, it illuminates a trouble LED and isolates the defective branch from the system -- enhancing life safety and protection while reducing troubleshooting time and maintenance costs.

     

    Features

    • Detects and isolates polling loop branches with complete or resistive shorts, and overload or defective polling loop devices on initial power up

    • Can be used to isolate burglary devices from fire devices, increasing life safety and protection

    • LED indicator reduces troubleshooting time and maintenance costs

    • Can be used on all qualified controls that support the ADEMCO V-Plex two-wire polling loop

    • Operates automatically on qualified controls without the need for changes to existing control hardware or software

    • Powered directly from the V-Plex two-wire polling loop

    • Can be placed on any major or minor branch in any configuration on the polling loop

    • Low power consumption

    • Designed to meet appropriate regulatory agency requirements

    Specifications:

      Operating Temperature:

    • 20C to +60C

      Operating Relative Humidity:

    • 0-95% non condensing

      Operating Voltage:

    • 7-14VDC, for V-Plex System

      Quiescent Current:

    • 1.2mA (LED off), 5.0mA (LED on)

      Loop Current:

    • 2 amps, max.

      Complete Short Detection:

    • <10 ohms

      Resistive Short Detection:

    • (10-400) ohms during normal polling; (10-800) ohms at application of polling loop power

      Power-On Short Detection:

    • ?15 ohms

      Overload Detection:

    • Loop power level is, 6VDC

      Dimensions:

    • 4 1/8" L x 9 1/16" W x 7/8" D

      Agency Listing:

    • UL1610
    • Commercial Burglary Alarm
    • central station alarm units
    • UL864
    • Commercial Fire Alarm
    • UL985
    • Residential Fire Alarm
    • UL1023
    • Household Burglary - alarm system units
    • UL609
    • Commercial Burglary - local alarm units
    • UL365
    • Commercial Burglary - police station alarm units
    • CUL
    • CSFM
    • FM
    • CE
       
     
     
     

    Enter your email for a chance to WIN $100 Amex Gift Card.