212-537-6540       212-202-3763       info@securitystoreusa.com
  1-800-363-2527    |      0

ELK PRODUCTS,INC. Elk Products,Inc. RELAY 12VDC @7A/ 10A 1I/ P 2O/ P - EK-941

ELK PRODUCTS,INC. Elk Products,Inc. RELAY 12VDC @7A/ 10A 1I/ P 2O/ P - EK-941
ELK PRODUCTS,INC.
EK-941
In Stock

Usually leaves our warehouse the same business day.

Return Policy

Rating: 0 [0]
ELK PRODUCTS,INC. Elk Products,Inc. RELAY 12VDC @7A/ 10A 1I/ P 2O/ P - EK-941

Description

The ELK-941 separates the steady or pulsing voltage from a single alarm output and directs this into two (2) different relay outputs. This is ideal for activating a two channel long-range radio or cellular transmitter, a two channel siren, strobe light, or bell from the single alarm outputs found in most alarm control panels. A steady voltage input activates Relay 1 (typical for burglary) while a pulsing voltage input activates Relay 2 (typical for fire). A 3 to 4 second verification delay time occurs before the relays activate. Either relay can be set to ignore the delay time and provide an immediate output for installations requiring a siren or bell test. A separate output is available for triggering a low current sounder or LED during the delay time. An optional jumper configures Relay 2 to pulse in a temporal coded bell pattern which meets ANSI Standard S3.41 for fire signaling. The input trigger can be either positive or negative (pull to ground).

  • Main Features
  • Height: 4.4"
  • Width: 3.0"
  • Depth: 1.2"
  • Limited Warranty: Lifetime
  • Marketing Information
  • The ELK-941 separates the steady or pulsing voltage from a single alarm output and directs this into two (2) different relay outputs. This is ideal for activating a two channel long-range radio or cellular transmitter, a two channel siren, strobe light, or bell from the single alarm outputs found in most alarm control panels. A steady voltage input activates Relay 1 (typical for burglary) while a pulsing voltage input activates Relay 2 (typical for fire). A 3 to 4 second verification delay time occurs before the relays activate. Either relay can be set to ignore the delay time and provide an immediate output for installations requiring a siren or bell test. A separate output is available for triggering a low current sounder or LED during the delay time. An optional jumper configures Relay 2 to pulse in a temporal coded bell pattern which meets ANSI Standard S3.41 for fire signaling. The input trigger can be either positive or negative (pull to ground).
  • Information
  • Name:RELAY 12VDC @7A/10A 1I/P 2O/PCategory:Surge Protection & Relays PowerUPC Code:762158009419

    Also known as

    • Elk Products,Inc. RELAY 12VDC @7A/ 10A 1I/ P 2O/ P - EK-941

    On Sale: