Viking Electronics PF-6A Power Fail Switch or Ground to

Viking Electronics PF-6A Power Fail Switch or Ground to
VIKING
VK-PF6A
 
Quantity
Custom Order

Custom orders usually ship in 1-2 weeks.

Reviews:

0 [0]

Free Shipping with this productOver $125

The PF - 6A power failure bypass system makes it possible to receive calls during phone system and power outages. The PF - 6A bypass unit connects 6 pre - assigned single line station phones directly to user - assigned C.O. trunks. A built - in ground start converter permits outbound calls from standard phones.
  • When the system is restored calls in progress are not lost. The PF - 6A bypass unit will reconnect phones to their station circuits after they become idle.
  • The PF - 6A can be configured to operate when power is lost or from an opening/closing of an alarm contact or manual closure.
  • Alternatively the PF - 6A can be used to convert six incoming ground start lines to loop start lines.
  • This accommodates installation of telephony equipment requiring loop start lines (example: key systems call sequencers answering machines voice mail etc.).
  • Prevents busy signals or unanswered calls during power and system failures.
  • Converts ground start lines to standard loop start lines.
  • Transfers six C.O. trunks directly to the designated analog station phones.
  • Stackable to increase capacity.
  • Allows user to receive calls as well as make calls during power or system failure.
  • Compatible with loop start lines or 48V ground start lines.
  • Automatic ground start converter eliminates "ground start buttons".
  • Power restoration will not interrupt calls in progress.
  • Operates on power failure or normally open - normally closed alarm contacts.
  • Made in the USA.
  • Power: 120 V AC/13.8V AC 1.25A UL listed adapter provided or 24 - 48V DC 100mA.
  • Dimensions: 211 mm x 160 mm x 46 mm ( 8.3" x 6.5" x 1.8" ).
  • Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95% non - condensing humidity.
  • Connections: (1) RJ21X (1) RJ11. - Ship Weight: 1.70 lbs.
  • Also known as

    • Viking Electronics Power Fail Switch or Ground to
    • Viking Electronics VK-PF-6A Power Fail Switch Or Ground To
    • Viking Network Switches Power Fail Transfer Switch and Ground to Loop Start Conv
    • Viking Electronics PF-6A Power Fail Bypass/Ground to Loop Start Converter
    • Transfers six C.O. trunks directly to the designated analog station phones
    • Stackable to increase capacity
    • Allows user to receive calls, as well as make calls during power or system failure
    • Compatible with loop start lines or 48V ground start lines
    • Automatic ground start converter eliminates "ground start buttons"
    • Power restoration will not interrupt calls in progress
    • Operates on power failure or normally open - normally closed alarm contacts
    • When the system is restored calls in progress are not lost. The PF - 6A bypass unit will reconnect phones to their station circuits after they become idle.
    • The PF - 6A can be configured to operate when power is lost or from an opening/closing of an alarm contact or manual closure.
    • Alternatively the PF - 6A can be used to convert six incoming ground start lines to loop start lines.
    • Prevents busy signals or unanswered calls during power and system failures.
    • Converts ground start lines to standard loop start lines.
    • Made in the USA.
    • Compatible with loop start lines or 48 Volt ground start lines
    • Connections: (1) RJ21X, (1) RJ11
    • 1 year warranty